LED Channel Retrofit Kit
-
Spec sheets: LSR 2 | LSR 3 | LSR 4 | LSR 6 | LSR 8
Photometry: Coming Soon
High-res images: LSR 4-footer with lens | LSR 8-footer, no lens
The LSR retrofit is a great application to save on installation cost, material cost and waste all while getting the benefit of upgrading your fluorescent luminaire to a highly efficient LED system. Available in any customer-provided width (as well as an adjustable option), the LSR can retrofit virtually any strip. A wide variety of lumen packages and lengths allows for flexibility in design and helps maximize energy savings. Optional frosted diffuser lenses help minimize glare and improve aesthetics. The LSR is made in the USA - in our Henderson, NC facility, utilizing mostly domestic and some foreign components.
- Applications: Suitable for most commercial, industrial and institutional applications - office, retail, warehouses, coves, valences
- Lumen Output: From 800 lm in the 2-foot version to 18,000 lm in the 8-footer
- Max Lumens Per Watt: Over 150
- Size Options: 2-foot, 3-foot, 4-foot, 6-foot, 8-foot
- Predicted L70 Lifetime: Up to 189,000 hours (calculated)
- Warranty: 5 year limited system warranty. 10-year extended warranty available on specific models
- Certifications: UL 1598 listed for US and Canada, suitable for damp locations. DesignLights Consortium qualified on specific configurations
- Made in the USA, in our Henderson, NC facility, utilizing mostly domestic and some foreign components. BAA compliant options are available
LSR Performance Chart
Size | Lumens | Watts | LPW | CRI / Color Temp | Voltages Available | DLC Listed | Predicted L70 Lifetime | Equivalency* | ||
---|---|---|---|---|---|---|---|---|---|---|
LSR 2 LW UV 835 | RCL 2 LW UV 835 | 2-foot | 837 | 8 | 104.7 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 1-lamp F17 T8 with LBF in a 2-foot strip |
LSR 2 LW UV 840 | RCL 2 LW UV 840 | 2-foot | 863 | 8 | 107.9 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 1-lamp F17 T8 with LBF in a 2-foot strip |
LSR 2 LW UV 850 | RCL 2 LW UV 850 | 2-foot | 889 | 8 | 111.1 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 1-lamp F17 T8 with LBF in a 2-foot strip |
LSR 2 MD UV 835 | RCL 2 MD UV 835 | 2-foot | 1,950 | 17.5 | 111.4 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F17 T8 with NBF, or 1-lamp F24 T5HO, in a 2-foot strip |
LSR 2 MD UV 840 | RCL 2 MD UV 840 | 2-foot | 2,011 | 17.5 | 114.9 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F17 T8 with NBF, or 1-lamp F24 T5HO, in a 2-foot strip |
LSR 2 MD UV 850 | RCL 2 MD UV 850 | 2-foot | 2,071 | 17.5 | 118.3 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F17 T8 with NBF, or 1-lamp F24 T5HO, in a 2-foot strip |
LSR 2 HI UV 835 | RCL 2 HI UV 835 | 2-foot | 3,085 | 23 | 134.1 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F24T5HO in a 2-foot strip |
LSR 2 HI UV 840 | RCL 2 HI UV 840 | 2-foot | 3,180 | 23 | 138.3 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F24T5HO in a 2-foot strip |
LSR 2 HI UV 850 | RCL 2 HI UV 850 | 2-foot | 3,275 | 23 | 142.4 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F24T5HO in a 2-foot strip |
LSR 2 VH UV 835 | RCL 2 VH UV 835 | 2-foot | 3,963 | 32 | 123.9 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 3-lamp F17 T8 with HBF in a 2-foot strip |
LSR 2 VH UV 840 | RCL 2 VH UV 840 | 2-foot | 4,086 | 32 | 127.7 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 3-lamp F17 T8 with HBF in a 2-foot strip |
LSR 2 VH UV 850 | RCL 2 VH UV 850 | 2-foot | 4,208 | 32 | 131.5 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 3-lamp F17 T8 with HBF in a 2-foot strip |
LSR 3 LW UV 835 | RCL 3 LW UV 835 | 3-foot | 1,241 | 11 | 112.8 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 1-lamp F25 T8 with LBF in a 3-foot strip |
LSR 3 LW UV 840 | RCL 3 LW UV 840 | 3-foot | 1,279 | 11 | 116.3 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 1-lamp F25 T8 with LBF in a 3-foot strip |
LSR 3 LW UV 850 | RCL 3 LW UV 850 | 3-foot | 1,318 | 11 | 119.8 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 1-lamp F25 T8 with LBF in a 3-foot strip |
LSR 3 MD UV 835 | RCL 3 MD UV 835 | 3-foot | 3,183 | 23 | 138.4 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F25 T8 with NBF in a 3-foot strip |
LSR 3 MD UV 840 | RCL 3 MD UV 840 | 3-foot | 3,282 | 23 | 142.7 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F25 T8 with NBF in a 3-foot strip |
LSR 3 MD UV 850 | RCL 3 MD UV 850 | 3-foot | 3,380 | 23 | 147 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F25 T8 with NBF in a 3-foot strip |
LSR 4 LW UV 835 | RCL 4 LW UV 835 | 4-foot | 2,305 | 18 | 128 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 1-lamp F32 T8 with NBF in a 4-foot strip |
LSR 4 LW UV 840 Image | RCL 4 LW UV 840 | 4-foot | 2,376 | 18 | 132 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 1-lamp F32 T8 with NBF in a 4-foot strip |
LSR 4 LW UV 850 Image | RCL 4 LW UV 850 | 4-foot | 2,447 | 18 | 136 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 1-lamp F32 T8 with NBF in a 4-foot strip |
LSR 4 MD UV 835 Image | RCL 4 MD UV 835 | 4-foot | 3,832 | 32 | 119.7 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F32 T8 with NBF, or 1-lamp F54 T5HO, in a 4-foot strip |
LSR 4 MD UV 840 Image | RCL 4 MD UV 840 | 4-foot | 3,950 | 32 | 123.4 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F32 T8 with NBF, or 1-lamp F54 T5HO, in a 4-foot strip |
LSR 4 MD UV 850 Image | RCL 4 MD UV 850 | 4-foot | 4,069 | 32 | 127.1 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F32 T8 with NBF, or 1-lamp F54 T5HO, in a 4-foot strip |
LSR 4 MH UV 835 Image | RCL 4 MH UV 835 | 4-foot | 4,829 | 36 | 134.1 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 3-lamp F32 T8 with LBF in a 4-foot strip |
LSR 4 MH UV 840 Image | RCL 4 MH UV 840 | 4-foot | 4,978 | 36 | 138.3 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 3-lamp F32 T8 with LBF in a 4-foot strip |
LSR 4 MH UV 850 Image | RCL 4 MH UV 850 | 4-foot | 5,128 | 36 | 142.4 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 3-lamp F32 T8 with LBF in a 4-foot strip |
LSR 4 HI UV 835 Image | RCL 4 HI UV 835 | 4-foot | 6,705 | 46 | 145.8 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with LBF in a 4-foot strip |
LSR 4 HI UV 840 Image | RCL 4 HI UV 840 | 4-foot | 6,913 | 46 | 150.3 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with LBF in a 4-foot strip |
LSR 4 HI UV 850 Image | RCL 4 HI UV 850 | 4-foot | 7,120 | 46 | 154.8 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with LBF in a 4-foot strip |
LSR 4 VH UV 835 Image | RCL 4 VH UV 835 | 4-foot | 8,901 | 68 | 130.9 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with HBF in a 4-foot strip |
LSR 4 VH UV 840 Image | RCL 4 VH UV 840 | 4-foot | 9,177 | 68 | 134.9 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with HBF in a 4-foot strip |
LSR 4 VH UV 850 Image | RCL 4 VH UV 850 | 4-foot | 9,452 | 68 | 139 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with HBF in a 4-foot strip |
LSR 6 LW UV 835 | RCL 6 LW UV 835 | 6-foot | 3,119 | 22 | 141.8 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F25 T8 with LBF in a 6-foot strip |
LSR 6 LW UV 840 | RCL 6 LW UV 840 | 6-foot | 3,216 | 22 | 146.2 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F25 T8 with LBF in a 6-foot strip |
LSR 6 LW UV 850 | RCL 6 LW UV 850 | 6-foot | 3,312 | 22 | 150.5 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F25 T8 with LBF in a 6-foot strip |
LSR 6 MD UV 835 | RCL 6 MD UV 835 | 6-foot | 6,482 | 54 | 120 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 4-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 MD UV 840 | RCL 6 MD UV 840 | 6-foot | 6,682 | 54 | 123.7 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 4-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 MD UV 850 | RCL 6 MD UV 850 | 6-foot | 6,883 | 54 | 127.5 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 4-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 HI UV 835 | RCL 6 HI UV 835 | 6-foot | 9,854 | 70 | 140.8 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 6-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 HI UV 840 | RCL 6 HI UV 840 | 6-foot | 10,159 | 70 | 145.1 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 6-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 HI UV 850 | RCL 6 HI UV 850 | 6-foot | 10,463 | 70 | 149.5 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 6-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 VH UV 835 | RCL 6 VH UV 835 | 6-foot | 12,423 | 95 | 130.8 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 8-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 VH UV 840 | RCL 6 VH UV 840 | 6-foot | 12,807 | 95 | 134.8 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 8-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 VH UV 850 | RCL 6 VH UV 850 | 6-foot | 13,192 | 95 | 138.9 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 8-lamp F25 T8 with NBF in a 6-foot strip |
LSR 8 LW UV 835 Image | RCL 8 LW UV 835 | 8-foot | 4,240 | 30 | 141.3 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F32 T8 with NBF in an 8-foot strip |
LSR 8 LW UV 840 Image | RCL 8 LW UV 840 | 8-foot | 4,371 | 30 | 145.7 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F32 T8 with NBF in an 8-foot strip |
LSR 8 LW UV 850 Image | RCL 8 LW UV 850 | 8-foot | 4,503 | 30 | 150.1 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F32 T8 with NBF in an 8-foot strip |
LSR 8 ML UV 835 Image | RCL 8 ML UV 835 | 8-foot | 6,125 | 44 | 139.2 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 1-lamp F96 T8HO, or 1-lamp F96 T12HO, in an 8-foot strip |
LSR 8 ML UV 840 Image | RCL 8 ML UV 840 | 8-foot | 6,314 | 44 | 143.5 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 1-lamp F96 T8HO, or 1-lamp F96 T12HO, in an 8-foot strip |
LSR 8 ML UV 850 Image | RCL 8 ML UV 850 | 8-foot | 6,504 | 44 | 147.8 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 1-lamp F96 T8HO, or 1-lamp F96 T12HO, in an 8-foot strip |
LSR 8 MD UV 835 Image | RCL 8 MD UV 835 | 8-foot | 8,033 | 64 | 125.5 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with NBF, 2-lamp F54 T5HO, or 2-lamp F96 T8 in an 8-foot strip |
LSR 8 MD UV 840 Image | RCL 8 MD UV 840 | 8-foot | 8,281 | 64 | 129.4 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with NBF, 2-lamp F54 T5HO, or 2-lamp F96 T8 in an 8-foot strip |
LSR 8 MD UV 850 Image | RCL 8 MD UV 850 | 8-foot | 8,530 | 64 | 133.3 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with NBF, 2-lamp F54 T5HO, or 2-lamp F96 T8 in an 8-foot strip |
LSR 8 MD HE UV 835 Image | RCL 8 MD HE UV 835 | 8-foot | 8,050 | 56 | 143 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with NBF, 2-lamp F54 T5HO, or 2-lamp F96 T8 in an 8-foot strip |
LSR 8 MD HE UV 840 Image | RCL 8 MD HE UV 840 | 8-foot | 8,299 | 56 | 147.4 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with NBF, 2-lamp F54 T5HO, or 2-lamp F96 T8 in an 8-foot strip |
LSR 8 MD HE UV 850 Image | RCL 8 MD HE UV 850 | 8-foot | 8,548 | 56 | 151.9 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with NBF, 2-lamp F54 T5HO, or 2-lamp F96 T8 in an 8-foot strip |
LSR 8 MH UV 835 Image | RCL 8 MH UV 835 | 8-foot | 10,765 | 78 | 138 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with HBF, or 2-lamp F96 T12HO, in an 8-foot strip |
LSR 8 MH UV 840 Image | RCL 8 MH UV 840 | 8-foot | 11,098 | 78 | 142.3 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with HBF, or 2-lamp F96 T12HO, in an 8-foot strip |
LSR 8 MH UV 850 Image | RCL 8 MH UV 850 | 8-foot | 11,431 | 78 | 146.5 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with HBF, or 2-lamp F96 T12HO, in an 8-foot strip |
LSR 8 HI UV 835 Image | RCL 8 HI UV 835 | 8-foot | 12,988 | 92 | 141.2 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F96 T8HO in an 8-foot strip |
LSR 8 HI UV 840 Image | RCL 8 HI UV 840 | 8-foot | 11,389 | 92 | 145.5 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F96 T8HO in an 8-foot strip |
LSR 8 HI UV 850 Image | RCL 8 HI UV 850 | 8-foot | 13,791 | 92 | 149.9 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F96 T8HO in an 8-foot strip |
LSR 8 VH UV 835 Image | RCL 8 VH UV 835 | 8-foot | 17,316 | 135 | 128.3 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F54 T5HO in an 8-foot strip |
LSR 8 VH UV 840 Image | RCL 8 VH UV 840 | 8-foot | 17,852 | 135 | 132.2 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F54 T5HO in an 8-foot strip |
LSR 8 VH UV 850 Image | RCL 8 VH UV 850 | 8-foot | 18,388 | 135 | 136.2 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F54 T5HO in an 8-foot strip |
LSR 2 LW UV FR 835 | RCL 2 LW UV FR 835 | 2-foot | 804 | 8 | 100.5 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 1-lamp F17 T8 with LBF in a 2-foot strip |
LSR 2 LW UV FR 840 | RCL 2 LW UV FR 840 | 2-foot | 828 | 8 | 103.6 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 1-lamp F17 T8 with LBF in a 2-foot strip |
LSR 2 LW UV FR 850 | RCL 2 LW UV FR 850 | 2-foot | 853 | 8 | 106.7 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 1-lamp F17 T8 with LBF in a 2-foot strip |
LSR 2 MD UV FR 835 | RCL 2 MD UV FR 835 | 2-foot | 1,852 | 17.5 | 105.8 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F17 T8 with LBF, or 1-lamp F24 T5HO, in a 2-foot strip |
LSR 2 MD UV FR 840 | RCL 2 MD UV FR 840 | 2-foot | 1,910 | 17.5 | 109.1 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F17 T8 with LBF, or 1-lamp F24 T5HO, in a 2-foot strip |
LSR 2 MD UV FR 850 | RCL 2 MD UV FR 850 | 2-foot | 1,967 | 17.5 | 112.4 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F17 T8 with LBF, or 1-lamp F24 T5HO, in a 2-foot strip |
LSR 2 HI UV FR 835 | RCL 2 HI UV FR 835 | 2-foot | 2,960 | 23 | 128.7 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F17 T8 with HBF, or 2-lamp F24 T5HO, in a 2-foot strip |
LSR 2 HI UV FR 840 | RCL 2 HI UV FR 840 | 2-foot | 3,052 | 23 | 132.7 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F17 T8 with HBF, or 2-lamp F24 T5HO, in a 2-foot strip |
LSR 2 HI UV FR 850 | RCL 2 HI UV FR 850 | 2-foot | 3,143 | 23 | 136.7 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F17 T8 with HBF, or 2-lamp F24 T5HO, in a 2-foot strip |
LSR 2 VH UV FR 835 | RCL 2 VH UV FR 835 | 2-foot | 3,804 | 32 | 118.9 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 3-lamp F17 T8 with HBF in a 2-foot strip |
LSR 2 VH UV FR 840 | RCL 2 VH UV FR 840 | 2-foot | 3,921 | 32 | 122.5 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 3-lamp F17 T8 with HBF in a 2-foot strip |
LSR 2 VH UV FR 850 | RCL 2 VH UV FR 850 | 2-foot | 4,039 | 32 | 126.2 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 3-lamp F17 T8 with HBF in a 2-foot strip |
LSR 3 LW UV FR 835 | RCL 3 LW UV FR 835 | 3-foot | 1,191 | 11 | 108.3 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 1-lamp F25 T8 with LBF in a 3-foot strip |
LSR 3 LW UV FR 840 | RCL 3 LW UV FR 840 | 3-foot | 1,228 | 11 | 111.6 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 1-lamp F25 T8 with LBF in a 3-foot strip |
LSR 3 LW UV FR 850 | RCL 3 LW UV FR 850 | 3-foot | 1,265 | 11 | 115 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 1-lamp F25 T8 with LBF in a 3-foot strip |
LSR 3 MD UV FR 835 | RCL 3 MD UV FR 835 | 3-foot | 3,055 | 23 | 132.8 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F25 T8 with NBF in a 3-foot strip |
LSR 3 MD UV FR 840 | RCL 3 MD UV FR 840 | 3-foot | 3,150 | 23 | 136.9 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F25 T8 with NBF in a 3-foot strip |
LSR 3 MD UV FR 850 | RCL 3 MD UV FR 850 | 3-foot | 3,244 | 23 | 141.1 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F25 T8 with NBF in a 3-foot strip |
LSR 4 LW UV FR 835 | RCL 4 LW UV FR 835 | 4-foot | 2,212 | 18 | 122.9 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 1-lamp F32 T8 with NBF in a 4-foot strip |
LSR 4 LW UV FR 840 Image | RCL 4 LW UV FR 840 | 4-foot | 2,280 | 18 | 126.7 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 1-lamp F32 T8 with NBF in a 4-foot strip |
LSR 4 LW UV FR 850 Image | RCL 4 LW UV FR 850 | 4-foot | 2,349 | 18 | 130.5 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 1-lamp F32 T8 with NBF in a 4-foot strip |
LSR 4 MD UV FR 835 Image | RCL 4 MD UV FR 835 | 4-foot | 3,640 | 32 | 115.5 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F32 T8 with LBF, or 1-lamp F54 T5HO, in a 4-foot strip |
LSR 4 MD UV FR 840 Image | RCL 4 MD UV FR 840 | 4-foot | 3,752 | 32 | 119.1 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F32 T8 with LBF, or 1-lamp F54 T5HO, in a 4-foot strip |
LSR 4 MD UV FR 850 Image | RCL 4 MD UV FR 850 | 4-foot | 3,865 | 32 | 122.7 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F32 T8 with LBF, or 1-lamp F54 T5HO, in a 4-foot strip |
LSR 4 MH UV FR 835 Image | RCL 4 MH UV FR 835 | 4-foot | 4,635 | 36 | 128.7 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 3-lamp F32 T8 with LBF in a 4-foot strip |
LSR 4 MH UV FR 840 Image | RCL 4 MH UV FR 840 | 4-foot | 4,778 | 36 | 132.7 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 3-lamp F32 T8 with LBF in a 4-foot strip |
LSR 4 MH UV FR 850 Image | RCL 4 MH UV FR 850 | 4-foot | 4,921 | 36 | 136.7 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 3-lamp F32 T8 with LBF in a 4-foot strip |
LSR 4 HI UV FR 835 Image | RCL 4 HI UV FR 835 | 4-foot | 6,436 | 46 | 139.9 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with LBF in a 4-foot strip |
LSR 4 HI UV FR 840 Image | RCL 4 HI UV FR 840 | 4-foot | 6,635 | 46 | 144.2 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with LBF in a 4-foot strip |
LSR 4 HI UV FR 850 Image | RCL 4 HI UV FR 850 | 4-foot | 6,834 | 46 | 148.6 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with LBF in a 4-foot strip |
LSR 4 VH UV FR 835 Image | RCL 4 VH UV FR 835 | 4-foot | 8,543 | 68 | 125.6 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with HBF in a 4-foot strip |
LSR 4 VH UV FR 840 Image | RCL 4 VH UV FR 840 | 4-foot | 8,807 | 68 | 129.5 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with HBF in a 4-foot strip |
LSR 4 VH UV FR 850 Image | RCL 4 VH UV FR 850 | 4-foot | 9,071 | 68 | 133.4 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with HBF in a 4-foot strip |
LSR 6 LW UV FR 835 | RCL 6 LW UV FR 835 | 6-foot | 2,994 | 22 | 136.1 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F25 T8 with LBF in a 6-foot strip |
LSR 6 LW UV FR 840 | RCL 6 LW UV FR 840 | 6-foot | 3,086 | 22 | 140.3 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F25 T8 with LBF in a 6-foot strip |
LSR 6 LW UV FR 850 | RCL 6 LW UV FR 850 | 6-foot | 3,179 | 22 | 144.5 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 2-lamp F25 T8 with LBF in a 6-foot strip |
LSR 6 MD UV FR 835 | RCL 6 MD UV FR 835 | 6-foot | 6,221 | 54 | 115.2 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 4-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 MD UV FR 840 | RCL 6 MD UV FR 840 | 6-foot | 6,413 | 54 | 118.8 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 4-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 MD UV FR 850 | RCL 6 MD UV FR 850 | 6-foot | 6,606 | 54 | 122.3 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 4-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 HI UV FR 835 | RCL 6 HI UV FR 835 | 6-foot | 9,457 | 70 | 135.1 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 6-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 HI UV FR 840 | RCL 6 HI UV FR 840 | 6-foot | 9,750 | 70 | 139.3 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 6-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 HI UV FR 850 | RCL 6 HI UV FR 850 | 6-foot | 10,042 | 70 | 143.5 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 6-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 VH UV FR 835 | RCL 6 VH UV FR 835 | 6-foot | 11,923 | 95 | 125.5 | 80 CRI / 3500K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 8-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 VH UV FR 840 | RCL 6 VH UV FR 840 | 6-foot | 12,292 | 95 | 129.4 | 80 CRI / 4000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 8-lamp F25 T8 with NBF in a 6-foot strip |
LSR 6 VH UV FR 850 | RCL 6 VH UV FR 850 | 6-foot | 12,660 | 95 | 133.3 | 80 CRI / 5000K | 120-277V, 347V | No | Up to 189,000 hrs (calculated) | Replaces 8-lamp F25 T8 with NBF in a 6-foot strip |
LSR 8 LW UV FR 835 Image | RCL 8 LW UV FR 835 | 8-foot | 4,070 | 30 | 135.7 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F32 T8 with NBF in an 8-foot strip |
LSR 8 LW UV FR 840 Image | RCL 8 LW UV FR 840 | 8-foot | 4,195 | 30 | 139.8 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F32 T8 with NBF in an 8-foot strip |
LSR 8 LW UV FR 850 Image | RCL 8 LW UV FR 850 | 8-foot | 4,321 | 30 | 144 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F32 T8 with NBF in an 8-foot strip |
LSR 8 ML UV FR 835 Image | RCL 8 ML UV FR 835 | 8-foot | 5,878 | 44 | 133.6 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 1-lamp F96 T8HO, or 1-lamp F96 T12HO, in an 8-foot strip |
LSR 8 ML UV FR 840 Image | RCL 8 ML UV FR 840 | 8-foot | 6,060 | 44 | 137.7 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 1-lamp F96 T8HO, or 1-lamp F96 T12HO, in an 8-foot strip |
LSR 8 ML UV FR 850 Image | RCL 8 ML UV FR 850 | 8-foot | 6,242 | 44 | 141.9 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 1-lamp F96 T8HO, or 1-lamp F96 T12HO, in an 8-foot strip |
LSR 8 MD UV FR 835 Image | RCL 8 MD UV FR 835 | 8-foot | 7,709 | 64 | 120.5 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with NBF, 2-lamp F54 T5HO, or 2-lamp F96 T8 in an 8-foot strip |
LSR 8 MD UV FR 840 Image | RCL 8 MD UV FR 840 | 8-foot | 7,948 | 64 | 124.2 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with NBF, 2-lamp F54 T5HO, or 2-lamp F96 T8 in an 8-foot strip |
LSR 8 MD UV FR 850 Image | RCL 8 MD UV FR 850 | 8-foot | 8,186 | 64 | 127.9 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with NBF, 2-lamp F54 T5HO, or 2-lamp F96 T8 in an 8-foot strip |
LSR 8 MD HE UV FR 835 Image | RCL 8 MD HE UV FR 835 | 8-foot | 7,726 | 56 | 137.3 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with NBF, 2-lamp F54 T5HO, or 2-lamp F96 T8 in an 8-foot strip |
LSR 8 MD HE UV FR 840 Image | RCL 8 MD HE UV FR 840 | 8-foot | 7,965 | 56 | 141.5 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with NBF, 2-lamp F54 T5HO, or 2-lamp F96 T8 in an 8-foot strip |
LSR 8 MD HE UV FR 850 Image | RCL 8 MD HE UV FR 850 | 8-foot | 8,204 | 56 | 145.7 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with NBF, 2-lamp F54 T5HO, or 2-lamp F96 T8 in an 8-foot strip |
LSR 8 MH UV FR 835 Image | RCL 8 MH UV FR 835 | 8-foot | 10,331 | 78 | 132.5 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with HBF, or 2-lamp F96 T12HO, in an 8-foot strip |
LSR 8 MH UV FR 840 Image | RCL 8 MH UV FR 840 | 8-foot | 10,651 | 78 | 136.6 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with HBF, or 2-lamp F96 T12HO, in an 8-foot strip |
LSR 8 MH UV FR 850 Image | RCL 8 MH UV FR 850 | 8-foot | 10,971 | 78 | 140.6 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F32 T8 with HBF, or 2-lamp F96 T12HO, in an 8-foot strip |
LSR 8 HI UV FR 835 Image | RCL 8 HI UV FR 835 | 8-foot | 12,465 | 92 | 135.5 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F96 T8HO in an 8-foot strip |
LSR 8 HI UV FR 840 Image | RCL 8 HI UV FR 840 | 8-foot | 12,850 | 92 | 139.7 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F96 T8HO in an 8-foot strip |
LSR 8 HI UV FR 850 Image | RCL 8 HI UV FR 850 | 8-foot | 13,236 | 92 | 143.9 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 2-lamp F96 T8HO in an 8-foot strip |
LSR 8 VH UV FR 835 Image | RCL 8 VH UV FR 835 | 8-foot | 16,619 | 135 | 123.1 | 80 CRI / 3500K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F54 T5HO in an 8-foot strip |
LSR 8 VH UV FR 840 Image | RCL 8 VH UV FR 840 | 8-foot | 17,133 | 135 | 126.9 | 80 CRI / 4000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F54 T5HO in an 8-foot strip |
LSR 8 VH UV FR 850 Image | RCL 8 VH UV FR 850 | 8-foot | 17,647 | 135 | 130.7 | 80 CRI / 5000K | 120-277V, 347V | Yes | Up to 189,000 hrs (calculated) | Replaces 4-lamp F54 T5HO in an 8-foot strip |