LED Troffer Retrofit Kit

The TLR is a retrofit for existing troffer luminaires, available in 2x2, 2x4 and 1x4 options. Easy lift and shift installation saves for labor costs. Each kit comes boxed with the necessary hardware for install. Frosted diffusers are available for use in louvered troffers to help minimize glare and improve aesthetics. The TLR is made in the USA - in Henderson, NC, utilizing mostly domestic and some foreign components.

  • Applications: For use in existing troffer luminaires
  • Lumen Output: From 2,500 lm to about 10,000 lm
  • Max Lumens Per Watt: 158
  • Size Options: 2x2, 2x4, 1x4
  • Predicted L70 Lifetime: Up to 189,000 hours (calculated)
  • Warranty: 5 year limited system warranty. 10 year extended warranty available on specific models
  • Certifications: UL 1598 listed for US and Canada, suitable for damp locations. DesignLights Consortium qualified on specific configurations
  • Made in the USA, in our Henderson, NC facility, utilizing mostly domestic and some foreign components. BAA compliant options are available

TLR Performance Chart

Catalog #
QPL/UL Reference #
SizeLumensWattsLPWCRI / Color TempVoltages AvailableDLC ListedPredicted L70 LifetimeEquivalency*
TLR 22 LW UV 835
Image
RTL 22 LW UV 835

2x22,50620125.380 CRI / 3500K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 2-lamp F17 T8 with NBF in a 2x2 troffer
TLR 22 LW UV 840
Image
RTL 22 LW UV 840

2x22,58320129.280 CRI / 4000K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 2-lamp F17 T8 with NBF in a 2x2 troffer
TLR 22 LW UV 850
Image
RTL 22 LW UV 850

2x22,6612013380 CRI / 5000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 2-lamp F17 T8 with NBF in a 2x2 troffer
TLR 22 MD UV 835
Image
RTL 22 MD UV 835

2x24,22830140.980 CRI / 3500K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 4-lamp F17 T8 with NBF in a 2x2 troffer
TLR 22 MD UV 840
Image
RTL 22 MD UV 840

2x24,35930145.380 CRI / 4000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 4-lamp F17 T8 with NBF in a 2x2 troffer
TLR 22 MD UV 850
Image
RTL 22 MD UV 850

2x24,48930149.680 CRI / 5000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 4-lamp F17 T8 with NBF in a 2x2 troffer
TLR 22 HI UV 835
Image
RTL 22 HI UV 835

2x24,89336135.980 CRI / 3500K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 2-lamp FB32 T8 with HBF in a 2x2 troffer
TLR 22 HI UV 840
Image
RTL 22 HI UV 840

2x25,04436140.180 CRI / 4000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 2-lamp FB32 T8 with HBF in a 2x2 troffer
TLR 22 HI UV 850
Image
RTL 22 HI UV 850

2x25,19636144.380 CRI / 5000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 2-lamp FB32 T8 with HBF in a 2x2 troffer
TLR 22 VH UV 835
Image
RTL 22 VH UV 835

2x25,86846127.680 CRI / 3500K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 4-lamp F17 T8 with HBF in a 2x2 troffer
TLR 22 VH UV 840
Image
RTL 22 VH UV 840

2x26,04946131.580 CRI / 4000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 4-lamp F17 T8 with HBF in a 2x2 troffer
TLR 22 VH UV 850
Image
RTL 22 VH UV 850

2x26,23146135.480 CRI / 5000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 4-lamp F17 T8 with HBF in a 2x2 troffer
TLR 24 VL UV 835
Image
RTL 24 VL UV 835

2x43,82026146.980 CRI / 3500K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 2-lamp F32 T8 with LBF in a 2x4 troffer
TLR 24 VL UV 840
Image
RTL 24 VL UV 840

2x42,93826151.580 CRI / 4000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 2-lamp F32 T8 with LBF in a 2x4 troffer
TLR 24 VL UV 850
Image
RTL 24 VL UV 850

2x44,0562615680 CRI / 5000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 2-lamp F32 T8 with LBF in a 2x4 troffer
TLR 24 LW UV 835
Image
RTL 24 LW UV 835

2x44,32830144.380 CRI / 3500K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 2-lamp F32 T8 with NBF in a 2x4 troffer
TLR 24 LW UV 840
Image
RTL 24 LW UV 840

2x44,46230148.780 CRI / 4000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 2-lamp F32 T8 with NBF in a 2x4 troffer
TLR 24 LW UV 850
Image
RTL 24 LW UV 850

2x44,59530153.280 CRI / 5000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 2-lamp F32 T8 with NBF in a 2x4 troffer
TLR 24 MD UV 835
Image
RTL 24 MD UV 835

2x45,9394413580 CRI / 3500K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 3-lamp F32 T8 with LBF in a 2x4 troffer
TLR 24 MD UV 840
Image
RTL 24 MD UV 840

2x46,12244139.180 CRI / 4000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 3-lamp F32 T8 with LBF in a 2x4 troffer
TLR 24 MD UV 850
Image
RTL 24 MD UV 850

2x46,30644143.380 CRI / 5000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 3-lamp F32 T8 with LBF in a 2x4 troffer
TLR 24 HI UV 835
Image
RTL 24 HI UV 835

2x46,93054128.380 CRI / 3500K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 3-lamp F32 T8 with NBF in a 2x4 troffer
TLR 24 HI UV 840
Image
RTL 24 HI UV 840

2x47,14454132.380 CRI / 4000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 3-lamp F32 T8 with NBF in a 2x4 troffer
TLR 24 HI UV 850
Image
RTL 24 HI UV 850

2x47,35954136.680 CRI / 5000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 3-lamp F32 T8 with NBF in a 2x4 troffer
TLR 24 VH UV 835
Image
RTL 24 VH UV 835

2x47,78964121.780 CRI / 3500K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 4-lamp F32 T8 with LBF in a 2x4 troffer
TLR 24 VH UV 840
Image
RTL 24 VH UV 840

2x48,02964125.580 CRI / 4000K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 4-lamp F32 T8 with LBF in a 2x4 troffer
TLR 24 VH UV 850
Image
RTL 24 VH UV 850

2x48,27064129.280 CRI / 5000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 4-lamp F32 T8 with LBF in a 2x4 troffer
TLR 24 SH UV 835
Image
RTL 24 SH UV 835

2x410,04168148.880 CRI / 3500K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 5-lamp F32 T8 with LBF in a 2x4 troffer
TLR 24 SH UV 840
Image
RTL 24 SH UV 840

2x410,35168153.480 CRI / 4000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 5-lamp F32 T8 with LBF in a 2x4 troffer
TLR 24 SH UV 850
Image
RTL 24 SH UV 850

2x410,6626815880 CRI / 5000K120-277V, 347VYesUp to 189,000 hrs (calculated)Replaces 5-lamp F32 T8 with LBF in a 2x4 troffer
TLR 14 LW UV 835

RTL 14 LW UV 835

1x42,50620125.380 CRI / 3500K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 1-lamp F32 T8 with HBF in a 1x4 troffer
TLR 14 LW UV 840

RTL 14 LW UV 840

1x42,58320129.280 CRI / 4000K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 1-lamp F32 T8 with HBF in a 1x4 troffer
TLR 14 LW UV 850

RTL 14 LW UV 850

1x42,6612013380 CRI / 5000K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 1-lamp F32 T8 with HBF in a 1x4 troffer
TLR 14 MD UV 835

RTL 14 MD UV 835

1x44,22830140.980 CRI / 3500K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 2-lamp F32 T8 with NBF in a 1x4 troffer
TLR 14 MD UV 840

RTL 14 MD UV 840

1x44,35930145.380 CRI / 4000K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 2-lamp F32 T8 with NBF in a 1x4 troffer
TLR 14 MD UV 850

RTL 14 MD UV 850

1x44,48930149.680 CRI / 5000K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 2-lamp F32 T8 with NBF in a 1x4 troffer
TLR 14 HI UV 835

RTL 14 HI UV 835

1x44,89336135.980 CRI / 3500K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 3-lamp F32 T8 with LBF in a 1x4 troffer
TLR 14 HI UV 840

RTL 14 HI UV 840

1x45,04436140.180 CRI / 4000K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 3-lamp F32 T8 with LBF in a 1x4 troffer
TLR 14 HI UV 850

RTL 14 HI UV 850

1x45,19636144.380 CRI / 5000K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 3-lamp F32 T8 with LBF in a 1x4 troffer
TLR 14 VH UV 835

RTL 14 VH UV 835

1x45,86846127.680 CRI / 3500K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 3-lamp F32 T8 with NBF in a 1x4 troffer
TLR 14 VH UV 840

RTL 14 VH UV 840

1x46,04946131.580 CRI / 4000K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 3-lamp F32 T8 with NBF in a 1x4 troffer
TLR 14 VH UV 850

RTL 14 VH UV 850

1x46,23146135.480 CRI / 5000K120-277V, 347VNoUp to 189,000 hrs (calculated)Replaces 3-lamp F32 T8 with NBF in a 1x4 troffer
*Photometrics conducted with A12 lenses. Adjustment factor for frosted diffusers = 0.958
**NOTE: Fixture equivalencies are estimates only and should be confirmed by photometric analysis or sample install to ensure adequate light levels are achieved.