LED 4' Vaportight High Bay

Durable materials and craftsmanship allows the VTL4 to withstand some of the harshest environments. The UL 5VA fiberglass housing will not melt or burn. Multiple hanging options available, including surface, chain and aircraft cable, for easy installation (more info below). Impact resistant acrylic and UV stabilized polycarbonate lenses are available as well. The VTL4 is made in the USA - in our Henderson, NC facility, utilizing mostly domestic and some foreign components.

  • Applications: Suitable for most industrial, retail and recreational low bay and high bay applications - warehouse, manufacturing facility, food processing, freezer, gymnasium, parking garage
  • Lumen Output: From 16,000 lm - 32,000 lm
  • Max Lumens Per Watt: 159
  • Size Options: 4-foot. 2-footer available as VTL2 (click here for VTL2 page)
  • Predicted L70 Lifetime: > 100,000 hours (calculated)
  • Warranty: 5 year limited system warranty
  • Certifications: UL 1598 listed for US and Canada, suitable for wet locations. DesignLights Consortium qualified on specific configurations. Other certifications: IP65, IP66, IP67, NEMA 4X, NSF, PSI 1500, RoHS
  • Made in the USA, in our Henderson, NC facility, utilizing mostly domestic and some foreign components. BAA compliant options are available
MountingOptionsUpdated2
    The VTL4 features multiple hanging options, including the Flexible Ceiling Mount (FCM), the Rigid Mounting Beam in both stainless steel and zinc-plated variations (RBS and RBZ), and the V-hook (VHK) for chain or cable mount.

VTL4 Performance Chart

Catalog #
QPL/UL Reference #
SizeLumensWattsLPWCRI / Color TempShieldingVoltages AvailableDLC ListedPredicted L70 LifetimeEquivalency*
VTL 4 LW UV FA 835
Image
WVL 4 LW UV FA 835

4-foot16,109122131.880 CRI / 3500KFrosted acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 LW UV FA 840
Image
WVL 4 LW UV FA 840

4-foot16,642122136.280 CRI / 4000KFrosted acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 LW UV FA 850
Image
WVL 4 LW UV FA 850

4-foot17,141122140.280 CRI / 5000KFrosted acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 MD UV FA 835
Image
WVL 4 MD UV FA 835

4-foot20,051156128.580 CRI / 3500KFrosted acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 MD UV FA 840
Image
WVL 4 MD UV FA 840

4-foot20,714156132.880 CRI / 4000KFrosted acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 MD UV FA 850
Image
WVL 4 MD UV FA 850

4-foot21,335156136.880 CRI / 5000KFrosted acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 HI UV FA 835
Image
WVL 4 HI UV FA 835

4-foot22,687169134.480 CRI / 3500KFrosted acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
VTL 4 HI UV FA 840
Image
WVL 4 HI UV FA 840

4-foot23,437169138.880 CRI / 4000KFrosted acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
VTL 4 HI UV FA 850
Image
WVL 4 HI UV FA 850

4-foot24,14016914380 CRI / 5000KFrosted acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
VTL 4 SH UV FA 835
Image
WVL 4 SH UV FA 835

4-foot30,546206148.280 CRI / 3500KFrosted acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
VTL 4 SH UV FA 840
Image
WVL 4 SH UV FA 840

4-foot31,394206152.480 CRI / 4000KFrosted acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
VTL 4 SH UV FA 850
Image
WVL 4 SH UV FA 850

4-foot32,242206156.580 CRI / 5000KFrosted acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
VTL 4 LW UV CA 835
Image
WVL 4 LW UV CA 835

4-foot16,366122133.980 CRI / 3500KClear acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 LW UV CA 840
Image
WVL 4 LW UV CA 840

4-foot16,907122138.380 CRI / 4000KClear acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 LW UV CA 850
Image
WVL 4 LW UV CA 850

4-foot17,415122142.580 CRI / 5000KClear acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 MD UV CA 835
Image
WVL 4 MD UV CA 835

4-foot20,371156130.680 CRI / 3500KClear acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 MD UV CA 840
Image
WVL 4 MD UV CA 840

4-foot21,044156134.980 CRI / 4000KClear acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 MD UV CA 850
Image
WVL 4 MD UV CA 850

4-foot21,676156138.980 CRI / 5000KClear acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 HI UV CA 835
Image
WVL 4 HI UV CA 835

4-foot23,049169136.580 CRI / 3500KClear acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
VTL 4 HI UV CA 840
Image
WVL 4 HI UV CA 840

4-foot23,81116914180 CRI / 4000KClear acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
VTL 4 HI UV CA 850
Image
WVL 4 HI UV CA 850

4-foot24,526169145.380 CRI / 5000KClear acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
VTL 4 SH UV CA 835
Image
WVL 4 SH UV CA 835

4-foot31,034206150.680 CRI / 3500KClear acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
VTL 4 SH UV CA 840
Image
WVL 4 SH UV CA 840

4-foot31,895206154.880 CRI / 4000KClear acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
VTL 4 SH UV CA 850
Image
WVL 4 SH UV CA 850

4-foot32,75620615980 CRI / 5000KClear acrylic120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
VTL 4 LW UV CP 835
Image
WVL 4 LW UV CP 835

4-foot16,071122131.580 CRI / 3500KClear polycarbonate120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 LW UV CP 840
Image
WVL 4 LW UV CP 840

4-foot16,603122135.880 CRI / 4000KClear polycarbonate120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 LW UV CP 850
Image
WVL 4 LW UV CP 850

4-foot17,101122139.980 CRI / 5000KClear polycarbonate120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 MD UV CP 835
Image
WVL 4 MD UV CP 835

4-foot20,004156128.280 CRI / 3500KClear polycarbonate120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 MD UV CP 840
Image
WVL 4 MD UV CP 840

4-foot20,665156132.580 CRI / 4000KClear polycarbonate120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 MD UV CP 850
Image
WVL 4 MD UV CP 850

4-foot21,285156136.480 CRI / 5000KClear polycarbonate120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
VTL 4 HI UV CP 835
Image
WVL 4 HI UV CP 835

4-foot22,634169134.180 CRI / 3500KClear polycarbonate120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
VTL 4 HI UV CP 840
Image
WVL 4 HI UV CP 840

4-foot23,382169138.580 CRI / 4000KClear polycarbonate120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
VTL 4 HI UV CP 850
Image
WVL 4 HI UV CP 850

4-foot24,084169142.780 CRI / 5000KClear polycarbonate120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
VTL 4 SH UV CP 835
Image
WVL 4 SH UV CP 835

4-foot30,475206147.980 CRI / 3500KClear polycarbonate120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
VTL 4 SH UV CP 840
Image
WVL 4 SH UV CP 840

4-foot31,32020615280 CRI / 4000KClear polycarbonate120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
VTL 4 SH UV CP 850
Image
WVL 4 SH UV CP 850

4-foot32,166206156.180 CRI / 5000KClear polycarbonate120-277V, 347V, 480VYes>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
*NOTE: Fixture equivalencies are estimates only and should be confirmed by photometric analysis or sample install to ensure adequate light levels are achieved.